40kVA/40kW 3-Phase Online Double Conversion Rack UPS, Long-Run (External Batteries)

$15,767.42 +GST

20kVA/20kW three-phase online double-conversion rack UPS in 3RU, for rack or tower installation. Connects to an external ±240VDC battery bank with a 10kW charger, and delivers full power at PF 1.0 with up to 97% efficiency. Configurable as 3/3, 3/1 or 1/1, with a 7-inch touch LCD, USB/RS232/RS485/Ethernet, intelligent slot for SNMP or AS400 cards, and parallel capability. RCM approved.

SKU: TT040ELR

RackPower 40kVA Three Phase Online Rack UPS – Long-Run

True Online Double Conversion | Three Phase | 40000VA/40000W | 4RU | Model TT040ELR

RackPower’s 40kVA three-phase rack UPS packs true online double-conversion protection into 4RU, for data rooms, server rooms and edge sites where rack space matters. It connects to external battery banks sized to your backup requirement, and mounts in a standard 19-inch rack or stands alone as a tower. With a true output power factor of 1.0, up to 96.8% online efficiency, a 3-level topology and full digital control, it delivers continuous, clean, regulated power with zero transfer time.

Key Features & Benefits

True Output Power Factor of 1.0
  • Delivers the full rated power – 40000W from 40kVA – with no compromise on capacity.
High Online Efficiency – Up to 96.8%
  • 3-level topology and full digital control reduce energy waste, minimise heat (approx. 1322W at full load) and cut electricity costs.
High Power Density – 40kW in 4RU
  • Mounts in a standard 19-inch rack (URK02 sliding rail kit available), or installs as a tower with support bases.
Long-Run Design with 8kW Charger
  • No internal batteries. Connects to an external ±240VDC battery bank (default 40 × 12V blocks per string), with a charger rated at 20% of output (8kW) to recharge large battery banks.
Wide Input Voltage Range (304–478Vac)
  • Operates reliably on unstable mains or generator supply without switching to battery, preserving battery health. Continues to run down to 228Vac with power derating.
Clean Input – PF >0.99, THDi <2%
  • Minimal impact on the upstream supply and generator, with no need for oversized input cabling or switchgear.
Full Three Phase Output
  • Three phase in / three phase out (3/3), delivering the full 40kVA rating across all three phases.
Intelligent Battery Management
  • Extends battery life through smart charging (2.25V/cell float, adjustable 2.2–2.35V/cell) and real-time battery diagnostics.
Self-Aging Function
  • Enables full-load testing without external load banks, saving energy and simplifying commissioning and maintenance.
7-Inch Touch LCD
  • Real-time system monitoring and control through an intuitive touchscreen with LED status indicators.
Robust Overload Capacity
  • 110% for 1 hour, 125% for 10 minutes and 150% for 1 minute, with a crest factor of 3:1.
Comprehensive Communications
  • USB, RS232, RS485, Ethernet, input and output dry contacts, EPO, temperature sensor input and cold start as standard. Intelligent slot for the UTTSNMP network card or UTTAS400 dry contact card.
Parallel Capable
  • Supports parallel operation for N+1 redundancy or added capacity with the optional parallel kit.
RCM Approved
  • Approved for installation in Australia and New Zealand, and built to IEC 62040-1, IEC 62040-2 and IEC 62040-3.

Technical Specifications

  • Model: TT040ELR
  • Rated power: 40kVA / 40kW
  • Topology: Online double conversion
  • Configuration: 3/3, full three phase
  • Input: 3P+N+PE, 380/400/415Vac (L-L), 40–70Hz
  • Input voltage range: 304–478Vac at full load; 228–304Vac with derating from 100% to 50%
  • Input power factor: >0.99; THDi <2% (linear load)
  • Max input current: 64A per phase
  • Output: 380/400/415Vac (L-L), 50/60Hz, ±1% voltage accuracy, 120° ±0.5° phase accuracy
  • Rated output current: 60A per phase
  • Output THDu: <1% linear load, <5% non-linear load
  • Efficiency: Up to 96.8% (online mode)
  • Battery: External, ±240VDC (default 40 × 12V blocks per string)
  • Charger capacity: 20% of rated output (8kW)
  • Max battery current: 95A
  • Recommended breakers: 80A 3P input, bypass and output; DC 125A battery
  • Recommended cables: 16mm² input, bypass and output; 35mm² battery; 10mm² PE
  • Display: LED + 7-inch touch LCD
  • Communications: USB, RS232, RS485, Ethernet, dry contacts, EPO, temperature input, cold start
  • Options: UTTSNMP SNMP card, UTTAS400 AS400 card, parallel kit, air filter, URK02 sliding rail kit
  • Standards: IEC 62040-1, IEC 60950-1, IEC 62040-2, IEC 62040-3
  • Approval: RCM (Australia & New Zealand)
  • IP rating: IP20
  • Noise (1m): 65dB at 100% load, 62dB at 45% load
  • Operating environment: 0–40°C, 0–95% RH non-condensing
  • Rack height: 4RU
  • Dimensions (W × D × H): 440 × 810 × 175mm
  • Net weight: 60kg

Ideal For:

  • Data Centres, Server and Comms Rooms, Edge Sites, Industrial Automation, Healthcare, Finance, Education, Government, Broadcasting, and more.